F100 — Compact UV Arc Flood Curing Lamp
Incure F100 covers an 8″×6″ curing area — 92% larger than the F400 or F500 portables — in a fixed bench-mount unit with rocker-switch simplicity. The F200 matches this footprint with higher output; the F200P adds programmable LCD control. The F100 is the entry-level bench-mount for labs and lower-throughput lines where a wide, even cure across the full area with no setup is the priority.
More Curing Area Than Any Portable in the F-Series
The F400 and F500 cure a 5″×5″ footprint in a handheld form — useful on the floor, but limited to parts that fit within that area. The F100 extends to 8″×6″, covering standard PCBs and multi-bond assemblies in a single pass without repositioning the part or the lamp. Pairs with the Incure B500 UV cure chamber for enclosed batch curing.
No Setup Between Cure Cycles
Rocker switch on, cure, rocker switch off. No exposure program to configure, no keypad, no LCD. The elapsed hour meter tracks total lamp hours for scheduled bulb replacement. For labs, repair stations, and lower-throughput production lines, this is the right level of control — fast to operate and nothing to misconfigure between shifts.
225 mW/cm² Across the Full 8″×6″ Area
400W metal halide arc lamp, UVA/UVB/visible to 420 nm. Uniform irradiance at 2.0″ working distance; 115 mW/cm² at 3.0″. ~2,000-hour lamp life. Auto-ranging 100–120/200–240 VAC. 11 lb compact bench-mount unit at 11″×10″×9″. Forced-air cooled. Optional Stand & Shield for wrap-around UV protection.
| Specifications | |
| Model | F100 |
| System Type | Compact Bench-Mount UV Flood Curing System |
| Lamp Type | 400W Metal Halide Arc Lamp |
| Spectral Output | UVA (315–400 nm), UVB (280–315 nm), Visible to 420 nm |
| Curing Area | 8″ × 6″ |
| Output Intensity | |
| UVA Peak Intensity @ 2.0″ | 225 mW/cm² |
| UVA Peak Intensity @ 3.0″ | 115 mW/cm² |
| Power & Electrical | |
| Input Voltage | 100–120 / 200–240 VAC ±10%, auto-ranging |
| Input Frequency | 50 / 60 Hz |
| Physical | |
| Weight | 11 lb |
| Dimensions | 11″ × 10″ × 9″ |
| Control | Rocker Switch With Standby Mode; Elapsed Hour Meter |
| Intensity Control | Standby Mode Reduces Lamp Power During Idle Operation |
| Safety / Shielding | Optional Stand & Shield / Wrap-Around UV Shield |
| Cooling | Forced Air |
| Lamp Life | ~2,000 hours |
| Chamber Compatibility | Compatible With Incure B500 UV Cure Chamber |
| Safety Equipment | UV Protective Goggles Included |
| Ordering | |
| P/N | F100 |
Peak UVA intensity measured at specified working distance with lamp at operating temperature. Actual intensity may vary with lamp age, ambient temperature, and working distance. Always wear UV-rated eye protection during operation.